Dos
  • Check for oil level daily
  • Fill oil ISOVG320 in gear boxes from size VF110 to VF18
  • Check the condition of the oil seals
  • When fitting the belt driven pulleys, make sure that the shafts are perfectly parallel and that the pulleys are aligned with each other
  • Provide overload protection to the electric motors
  • Protect motor from water and humidity
Donts
  • Do not block the breather holes if its is provided. This may lead to the internal pressure and consequent leakage of oil from oil seals and rubber caps.
  • Do not paint on the oil seals Do not hammer the output / input shafts while fitting the pulley or any other drive mechanism. This may lead to breakage of internals
  • Incorrect alignment can cause damage to the motor and the input shaft bearings
  • Avoid over-tensioning the belts since excess tension can cause bearing failure in the gear box
  • Do not run the motor in high voltage fluctuation
  • Do not disturb the original brake settings
  • Do not give brake supply connections separately as it is already connected internally
-
-